Walk any building you service and you’ll find lithium-ion batteries everywhere. Laptops charge at every desk, cordless tools charge in the shop, and e-bikes lean against the lobby wall. Meanwhile, more owners are adding battery storage to their solar arrays or wind turbines, often in a garage, a utility room, or a pad outside the back door.

When owners ask you what protection they need, the answer depends on which battery you’re talking about. So this guide breaks lithium-ion battery fire protection into two general parts, so you can give owners clear, code-based recommendations for both.

Why Does Lithium-Ion Battery Fire Protection Need Its Own Plan?

Lithium-ion batteries need a dedicated plan because a cell in thermal runaway makes its own heat and flammable gas. For example, damage, overcharging, manufacturing defects, or heat exposure can start the reaction, and one failing cell can drive its neighbors into runaway.

As a result, a battery fire can keep going after the visible flame goes out, release toxic and flammable gases, and reignite hours later. NFPA Journal described this gap between widespread use and safety in The Lithium-Ion Challenge. For that reason, the protection strategy has to account for prevention, early warning, cooling, and containment, not only extinguishment.

How Should Property Owners Manage Personal Devices and Power Tools?

Start with prevention, because most device fires begin with a damaged, counterfeit, or mismatched battery or charger. NFPA’s Lithium-Ion Battery Safety guidance supports a short list of controls you can recommend to every owner:

  • Buy listed products: Require batteries, chargers, and devices listed by a nationally recognized testing laboratory, like UL Solutions, and ban aftermarket or counterfeit batteries.
  • Use the manufacturer’s charger: Mismatched chargers are a common cause of overcharging, so keep each charger with its own device or tool. Be sure to regularly inspect the chargers as well and remove them from service immediately if they are damaged.
  • Designate charging areas: Charge tools and equipment, powered devices, e-bikes, and scooters on noncombustible surfaces, away from exits, combustible storage, and sleeping areas.
  • Stop using damaged batteries: Pull any battery that swells, leaks, smells odd, overheats, or makes noise, and take it out of service right away.
  • Quarantine and recycle: Store damaged or spent batteries in a covered metal container away from combustibles and then send them to a battery recycler instead of the trash.
  • Train occupants: Finally, staff should know the warning signs, how to evacuate, and when to call 911.

In commercial buildings, charging areas also deserve a look during your inspection. Confirm that smoke or heat detection covers the space, that sprinklers aren’t obstructed by charging racks, and that the area has the right extinguisher nearby.

What Suppression Works on Device and Tool Battery Fires?

In most cases, cooling works best, and water is the most effective cooling agent for small lithium-ion cells. An extinguisher can control flames and burning surroundings, but it won’t stop thermal runaway inside the cells.

The table below matches common situations to the response you should recommend.

Situation Recommended Response
Device smoking, hissing, or swelling, no flame Unplug it if safe, move people away, and call 911. Don’t handle a hot battery with bare hands.
Small flaming device or tool battery Evacuate the area and call 911. Trained staff may use water or a water-based extinguisher to cool the battery and surroundings if it’s safe.
Fire in energized equipment around the battery Use an extinguisher listed for Class C hazards on the electrical equipment, then keep cooling the battery area.
E-bike or scooter battery fire Evacuate immediately. These packs can release large volumes of gas and fire, so leave suppression to the fire department.
Battery fire that seems out Treat it as active. Keep it isolated, because reignition is common, and let the fire department confirm it’s safe.

Also keep in mind that NFPA 10, Standard for Portable Fire Extinguishers, doesn’t define a separate fire class for lithium-ion batteries. So review any product marketed as a “lithium-ion extinguisher” against its actual listing and test basis before you recommend it.

What Does NFPA 855 Require for On-Site Solar and Wind Battery Storage?

While Fire Tech doesn’t often get into NFPA 855, Standard for the Installation of Stationary Energy Storage Systems, we recommend you #NeverStopLearning. As alternative energy becomes more common, familiarizing yourself with additional standards is always a good idea. The 2026 edition of NFPA 855 governs battery storage paired with solar panels or wind turbines once it exceeds the standard’s thresholds. However, the path depends on the occupancy.

One- and Two-Family Dwellings

First, NFPA 855 has a dedicated chapter for residential Energy Storage Systems (ESS). Its key provisions include these requirements:

  • Owners need systems listed to UL 9540, installed per the manufacturer’s instructions.
  • NFPA 855 caps individual units at 20 kWh.
  • It also caps aggregate capacity at 40 kWh in utility closets and storage spaces, and 80 kWh in attached or detached garages, accessory structures, and outdoor locations.
  • Units need 3 feet of separation from each other unless large-scale fire testing supports closer spacing.
  • ESS can’t go in living areas or sleeping rooms.
  • Rooms and garages with ESS need smoke alarms or, where smoke alarms aren’t suitable, heat detection interconnected with the dwelling’s alarms.
  • Units exposed to vehicle traffic need approved impact protection, such as bollards.

Commercial and Multifamily Properties

Above the residential path, the full standard applies, and the 2026 edition raises the bar. Thresholds apply per fire area, so several small systems can add up to a regulated ESS. In addition, owners should expect these requirements:

  • A hazard mitigation analysis for most lithium-ion installations
  • Large-scale fire test data that matches the installed configuration
  • Automatic sprinklers per NFPA 13 as the baseline, with alternatives accepted only when fire testing and an HMA support them
  • Explosion control through deflagration venting under NFPA 68 or explosion prevention under NFPA 69, where required
  • A written emergency response plan with annual review and yearly refresher training

Also, the Fire Protection Research Foundation’s Sprinkler Protection Guidance for Lithium-Ion Based Energy Storage Systems is a useful reference when you discuss design density with the owner and the AHJ.

What Fire Protection Layers Belong Around On-Site Battery Storage?

Build protection in layers, because each one covers a different stage of a battery event. For most owners, a complete approach includes these steps:

  1. Locate it right. Put the ESS in an approved location with the required separation from doors, windows, and other units.
  2. Separate it. Use rated construction around indoor installations so a battery event stays a battery event.
  3. Detect early. Combine smoke or heat detection with off-gas detection where the design calls for it, and tie signals into the fire alarm system.
  4. Cool and control. Provide sprinkler protection designed to the test data, and keep sprinklers clear of battery cabinets.
  5. Vent the gas. Coordinate explosion control and exhaust with the mechanical and electrical trades.
  6. Plan the response. Post signage and disconnect locations, and give the fire department a current emergency response plan.

Then keep it maintained. Detection, sprinklers, and exhaust only protect the property if someone inspects, tests, and maintains them on schedule.

What’s at Stake for Owners and Contractors?

A single charging mistake or an undersized ESS layout can turn a routine battery failure into a building fire. Meanwhile, owners often assume that a battery vendor’s installation covers fire protection, which leaves gaps no one owns, and that means possible danger to life and property.

That’s where you come in. The contractor or inspector who can explain both hazards in plain terms becomes the owner’s trusted guide. For a refresher on how special hazards differ from traditional protection, see Traditional vs. Special Hazards Fire Suppression.

How Fire Tech Helps You Advise Owners With Confidence

Battery hazards change faster than many training programs, and owners expect you to have answers today. For nearly 40 years, Fire Tech Productions has helped fire protection and life safety professionals master the standards they use every day. As a NICET Recognized Training Provider and ICC Preferred Education Provider, we offer 300+ courses, workshops, and study materials.

  1. Choose Your Training: From online courses and hands-on workshops to exam prep bundles and in-person training, we have the resources you need.
  2. Master the Codes: Gain the knowledge and confidence to learn fire protection standards, pass your exams, and confidently mitigate risks.
  3. Get Certified: Become a fire protection expert and propel your career.

Build your foundation with Fire Tech’s Special Hazards Online Courses and the Special Hazards Level I Book Set. Next, sharpen your extinguisher knowledge with our Portable Extinguishers training, and pick up the current NFPA 855 from our NFPA Codes and Standards collection.

Browse Courses →


Frequently Asked Questions

Does NFPA 855 apply to a home battery paired with solar panels?

Yes, when the system falls within the standard’s residential provisions. NFPA 855 covers residential ESS with limits on unit size, aggregate capacity, location, and spacing. Then check the edition your jurisdiction has adopted, because many AHJs enforce these rules through the IRC or the fire code instead of NFPA 855 directly.

Can a standard ABC extinguisher put out a lithium-ion battery fire?

Not reliably. An ABC extinguisher can knock down flames and burning surroundings, but it doesn’t cool cells in thermal runaway, so reignition remains likely. Water cools more effectively, and the safest move for anything larger than a small device is to evacuate and call the fire department.

Where should employees charge power tools, scanning devices and e-bikes?

Charge them in a designated area on noncombustible surfaces, away from exits, combustible storage, and sleeping areas. The space should have detection and sprinkler coverage, plus an extinguisher nearby. Also, set rules that require listed batteries and manufacturer chargers.

Do battery rooms for solar or wind storage need sprinklers?

In most commercial installations, yes. NFPA 855 uses NFPA 13 sprinklers as the baseline for fire control and suppression. The AHJ may accept an alternative when fire testing and a hazard mitigation analysis support it, so confirm the design basis early.

How should owners store damaged lithium-ion batteries?

First, isolate them in a covered metal container away from combustibles until a battery recycler can take them. Also, never put them in the trash or a general recycling bin. Finally, label the container and keep it out of exit paths.


Sources

Inspection & Testing of Water-Based Systems
Basic Reference Text

$109.99

The fifteen chapter Inspection & Testing of Water-Based Systems Basic Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.


The Inspection & Testing of Water-Based Systems Basic Reference Text covers:

 

I&T Sprinkler basic reference text

Inspection & Testing of Water-Based Systems
Intermediate Reference Text

$109.99

The fifteen chapter Inspection & Testing of Water-Based Systems Intermediate Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exams.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Inspection & Testing of Water-Based Systems Intermediate Reference Text covers:

 

I&T intermediate reference text, Sprinklers

Inspection & Testing of Fire Alarm Systems
Reference Text

$139.99

This fourteen chapter Inspection & Testing of Fire Alarm Systems Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Inspection & Testing of Fire Alarm Systems Level I & II Online Course is a perfect study package for those preparing for the NICET Inspection & Testing of Fire Alarm Systems exams.
This book is a fundamental reference covering Inspection & Testing of Fire Alarm Systems concepts. The numerous NFPA 72 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


The Inspection & Testing of Fire Alarm Systems Reference Text covers:

 

I&T fire alarm systems reference text

 

Water-Based Systems Layout Basic Reference Text

$119.99

The twenty chapter Water-Based Systems Layout Basic Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 237 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Water-Based Systems Layout Basic Reference Text covers:

 

Sprinkler reference text

Water-Based Systems Layout Intermediate Reference Text

$139.99

The twenty three chapter Water-Based Systems Layout Intermediate Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 339 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level II exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Water-Based Systems Layout Intermediate Reference Text covers:

 

Water based systems, sprinkler intermediate reference text

Water-Based Systems Layout Advanced General Plans Reference Text

$139.99

The sixteen chapter Water-Based Systems Layout Advanced General Plans Reference text is an invaluable reference for Water-Based Systems Layout professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, General Plans exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Water-Based Systems Layout Advanced General Plans Reference Text covers:

 

Sprinkler systems general plans reference text

Water-Based Systems Layout Advanced Hydraulics Reference Text

$139.99

The eight chapter Water-Based Systems Layout Advanced Hydraulics Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 232 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, Hydraulics exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Water-Based Systems Layout Advanced Hydraulics Reference Text covers:

 

Advanced hydraulics sample reference text page

Water-Based Systems Layout Basic & Intermediate Reference Texts

$229.99

Two GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



Water-Based Systems Layout Basic Reference Text

$119.99

The twenty chapter Water-Based Systems Layout Basic Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 237 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

 



Water-Based Systems Layout Intermediate Reference Text

$139.99

The twenty three chapter Water-Based Systems Layout Intermediate Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 339 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level II exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


Detailed contents can be found in the description for the individual text.

 

Water-Based Systems Layout Basic, Intermediate, General Plans & Hydraulics Reference Texts

$449.99

Four GREAT Reference Texts, One Low Price! Save when you order the Complete Water-Based Reference Library. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.


Detailed descriptions can be found in the “Learn More” link for each individual text.

Water-Based Systems Layout General Plans & Hydraulics
Reference Texts

$249.99

Two GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



Water-Based Systems Layout General Plans Reference Text

$149.99

The sixteen chapter Water-Based Systems Layout Advanced General Plans Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 335 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, General Plans exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.



Water-Based Systems Layout Hydraulics Reference Text

$149.99

The eight chapter Water-Based Systems Layout Advanced Hydraulics Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 232 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, Hydraulics exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


Detailed contents can be found in the description for the individual text.

 

Inspection & Testing of Water-Based Systems Basic & Intermediate Reference Texts

$189.99

Two GREAT Reference Texts, One Low Price! $ave when you order the combo package. Loaded with NFPA 25 references, these texts will become a valuable asset both in the field and office.



Inspection & Testing of Water-Based Systems Basic Reference Text

$109.99

The fifteen chapter Inspection & Testing of Water-Based Systems Basic Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

 



Inspection & Testing of Water-Based Systems Intermediate Reference Text

$109.99

The fifteen chapter Inspection & Testing of Water-Based Systems Intermediate Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


Detailed contents can be found in the description for the individual text.

 

Special Hazards Basic Reference Text

$139.99

The 18 chapter Special Hazards Basic Reference text is an invaluable reference for Special Hazards’ professionals. This text contains 265 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Special Hazards Level I exam.

*Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


The Special Hazards Basic Reference Text covers:

Fire Alarm Systems – Basic Reference Text

$119.99

This thirteen chapter Fire Alarm Systems – Basic Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level I Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level I exam.
This book is a fundamental reference covering Fire Alarm Systems concepts. The numerous NFPA 70 2014 and NFPA 72 2016 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


The Fire Alarm Systems Reference Text covers:

Fire Alarm Systems – Basic, Intermediate & Advanced Texts, Inspection & Testing of Fire Alarms Text, Inspection & Testing of Water-Based Systems Basic & Intermediate Texts, Special Hazards Text, and Water-Based Systems Layout Basic, Intermediate, General Plans & Hydraulics Reference Texts

$999.99

Eleven GREAT Reference Texts, One Low Price! Save when you order the Complete Fire Tech Reference Library. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.


Detailed descriptions can be found in the “Learn More” link for each individual text.

Prior to joining Fire Tech Productions, Tom Frericks Jr. owned Copp Integrated Systems in Dayton, OH.  He served on the NSCA board of directors for 11 years and is currently serving on the ASCET and NICET boards.  Tom received NSCA’s 2018 Per Haugen Lifetime Achievement Award for his time and dedication to the association.

All Inclusive Pricing includes workshop registration, hotel stay, meals & shuttle to/from training site.

Live in the area? Call our office at 937-434-3473 for Non-Inclusive Pricing.

Packages Include:

The following NICET approved Standards and Fire Tabs in addition to your Online Course purchase:

Level I: NFPA 70 2011 and NFPA 72 2013

Level I & II: NFPA 70 2011, NFPA 72 2013 and IBC 2012

Level III: NFPA 70 2011, NFPA 72 2013, IBC 2012 and NFPA 101 2012

What Is a Webinar?

  • Four hours of supplemental content expanding on course lesson material.
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 70, NFPA 72, IBC, and NFPA 101 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 70 2014, NFPA 72 2016 and Ugly’s
  • Level II: NFPA 70 2014, NFPA 72 2016 and IBC 2015
  • Level III: NFPA 70 2014, NFPA 72 2016, NFPA 101 2015 and IBC 2015
  • We know preparing for a NICET exam doesn’t happen overnight. Fire Tech’s programs are designed to guide you every step of the way. If you have followed our NICET prep program, and have taken the exam within thirty (30) days of successfully completing your course* and do not pass, Fire Tech Productions will provide the following support:

    – Evaluation of your exam results to uncover subject matter weaknesses;
    – Recommendations for improved exam preparation & testing; and
    – Extended access to appropriate prep course(s)

    Students must contact Fire Tech Productions and restart their study within ninety (90) days of failing the exam.

    *Our courses are guaranteed for exam success when students who possess the level of experience (corresponding with the certification requirements) have studied each lesson & taken and passed each quiz/exam within each level of training, up to and including their exam level. Students must have also used current NICET-permitted references for their study and exam.

    Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • 10-15 minute videos accompany each individual lesson.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 13, 13D, 13R, 14, 20 and 291 2016 and NFPA 22 2013 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 13, 13D, 13R and 291 2016
  • Level II: NFPA 13, 14, 20 and 291 2016
  • Level III – General Plans: NFPA 13, 14, 20 2016 and 22 2013
  • Level III – Hydraulics: NFPA 13, 14, 20 and 291 2016
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 12 and 70 2011, NFPA 72 2013 and NFPA 2001 2012 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved Standards in addition to your Online Course:

  • Level I: NFPA 12 and 70 2011, NFPA 72 2013 and NFPA 2001 2012
  • Online Courses Include:

  • 90 days (single level purchase) / 120 days (multiple level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 72 2013 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I & II: NFPA 72 2013
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I & II: NFPA 25 2014