| A FIRE PROTECTION TRAINING COMPANY
SIGN IN

Firestop Applications. Photo courtesy of the International Firestop Council

 

Nothing is trending more these days than talk about the coronavirus. Did you know that fire protection measures may help contain the spread of diseases? Air resistant firestop sealants and devices can restrict not only the movement of smoke and sound, but also of air pathogens. Firestop systems are often required to be rated to restrict the passage of air, a very important feature in healthcare occupancies.

In our last article we talked about the six (6) main strategies for fire protection (Are you able to name them all?). Three (3) of them pertain to the construction realm, they are equally important and make up what can be considered The Life Safety Triangle1: Detection, Suppression and Containment. Firestop is fundamental to guarantee containment, yet it is often the least known subject amongst fire protection professionals that deal with fire sprinklers and fire alarm systems. Meanwhile, third party inspections for firestop systems is being enforced more regularly in new construction projects and, without training, most trades rush to obtain the first red firestop product they can find; however, without understanding any of what is really needed to restore the integrity of fire rated assemblies.

Let’s think about a fire developing in a room inside a building of a determined occupancy where the life safety triangle is being used correctly. First, smoke will be picked up by detectors and notification devices will make occupants aware. If manual suppression is ineffective, sprinklers will activate and help control the growth of fire. At this stage, smoke and toxic gases are expected to be produced. Proper containment will help confine not only fire, but also smoke and toxic gases in the room of origin.

CONTAINMENT

… how important is it, really? Consider the MGM Grand Hotel and Casino fire, Las Vegas, in 1980 where 85 people lost their lives and 650 were injured. 61 deaths were reported to be from the upper floors of the hotel (19th to 24th floors) even though the fire started on the first floor, in one of the restaurants.  A total of 75 people (out of 85) died from smoke inhalation and carbon monoxide poisoning.2

The severity of the fire was aided by many factors such as lack of sprinklers in the casino and restaurant areas, but mostly because of how easy the smoke was able to spread throughout the building due to joints, shafts and egress stairwells —  allowing the fire to quickly make its way to upper floors.

MGM Grand Hotel and Casino fire, 1980, Las Vegas, Nevada2

Containment is a component of Passive Fire Protection, in which the aim is to confine a fire using a concept called compartmentation; Compartmentation seeks to restrict spread of fire by dividing a building into separate smaller “fire” compartments through the use of fire-resistance rated walls and floors.

 

Requirements of these fire rated assemblies are given by building codes based on the type of construction and occupancy. For example, fire resistance attributes will differ greatly between a poured concrete and steel commercial high-rise building when compared to a single-family, wood frame home.

Fire rated walls and floors to create fire compartments. Egress components such as exit access and stairways usually call for fire rated assemblies.1

FIRESTOP

 

In order to effectively resist the effects of fire and smoke, a fire-rated assembly must be complete and whole. At a certain point, in all construction projects, trades will start to install ducts, pipes, conduits, trays and cables — and these must pass from room to room, and from one floor to the next. Gaps (called joints) will start appearing when walls or floors meet other walls or floors. When any of these situations occur, the integrity of the fire rated assembly is compromised. The solution to these problems is Firestopping. Firestop is the fire protection system made of various components used to seal openings and joints that restores the integrity of fire rated assemblies.

Firestop in a through-penetration and head-of-wall joint. Credits to LSS® and HILTI

Firestop solutions are explicitly required by the 2018 International Building Code for penetrations and joints, as follows.

Section 714.4.1.2 – Through-penetration firestop system

“Through-penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E 814 or UL 1479…”

Section 715.3 – Fire resistant joint systems

“Fire-resistant joint systems shall be tested in accordance with the requirements of either ASTM-E1966 or UL 2079…”

 

Please note how the word system is used, indicating that there is more than one factor involved (so it’s not only about a firestop product). This is very important; there is an old misconception among installers which have led them to believe any given red caulk or foam is enough to satisfy code and/or inspectors´ requirements. This is far from the truth and is the origin of many costly construction mistakes. By the end of this article, the reader will be able to identify all components necessary to choose the correct solution for almost any application.

FIRESTOP SYSTEM TESTING AND LISTINGS

As we saw earlier, firestop systems must be installed as tested in accordance to a certain UL or ASTM standard.  It is very impractical to try to replicate a fire test for each construction project or application, so we rely on third party facilities who can test many different configurations of materials and products. Each test lab will then publish its own listing directory of approved firestop system applications.

Sample of popular certification marks from third party agencies used within the building products market.4

FIRESTOP

Understanding these test standards and the testing process is key to designing fire resistant systems. In this article we are going to explore through penetrations and joint systems.

 

F-RATING AND T-RATING

 

Have you ever heard of a 2-hour fire rated slab? How about a 1-hour fire rated drywall? These hourly ratings talk about how a determined assembly has passed a fire test in a lab. If we talk specifically about firestop, there are two possible ratings you can obtain from a firestop system assembly test: An F-rating and a T-rating (F stands for flame and T stands for Temperature).

 

F-rating

An F-rating is the duration of time in which flames do NOT pass through the system. For example, if during the test of a firestop system in a wall, according to ASTM E814, the flames were successfully contained from passing from one side to the other for at least 3 hours, the firestop system will obtain an F-rating = 3 hours.

T-Rating

Try to think of the T-rating as more or less the same concept as the F-rating but, instead of flames, you are trying to contain temperature: T-rating is the time period that the penetration firestop system, including the penetrating item, limits the maximum temperature rise to 325°F (163°C) above its initial temperature through the penetration on the non-fire side when tested in accordance with ASTM E814. (The IBC does not require a T-rating for wall penetrations, only on floor penetrations).

 

Does it really mean that if you have a firestop system with an F-rating of 2 hours, that it will resist the passage of flames for 2 hours in a real-life fire scenario? Not necessarily. Real-life performance may be better or may be worse depending on the actual fire. During the test, all the components are exposed to test conditions that follow the ASTM E814 time-temperature curve (see figure below). So, all test conclusions are according to a fire that behaves just like the test one. It works well in setting a benchmark.

Time-Temperature curve. At 10 minutes, fire reaches a temperature of 1300o F. Many common construction materials melt below this point.5

TESTING THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS

Typical tests will include a certain fire rated wall or floor assembly and different through penetrating items. A single test can be used to seek approval (and therefore listing) for more than one application: single or multiple items in a single penetration, different size of openings, different materials for penetrating items and different firestop products or devices. A specific system will be awarded a rating only after the required time and after withstanding a Hose Stream Test for integrity. This test is performed by aiming a hose stream of water to the assembly at a fixed psi (pounds per square inch) value and duration to simulate the intense pressure that builds up due to the accumulation of hot air, steam and gases during a fire. 

Different through-penetration applications, before fire test.6

Inside furnace, during fire test.6

ASTM E814 also gives the parameters to test membrane penetrations. The difference between a through penetration and a membrane penetration is that a through penetration has an opening that passes entirely through the fire rated assembly, while a membrane penetration has an opening that passes only through one (1) side of the assembly (such is the case of a recessed electrical box in a wall, for example). If you are panicking due to realizing you might have NEVER used a firestop solution with electrical boxes… don’t worry! Most of the time you don’t need to. But please, check the IBC and your local regulations to understand when it’s indeed required.

Inside furnace, during fire test.6

Through penetration vs membrane penetration. Source: archtoolbox7

TESTING JOINT SYSTEMS

Typical joint systems are tested to obtain F-ratings and T-ratings. They must undergo a similar hose stream test just as through penetrations.  Most joint systems also tested to endure cyclic movement as joints often need to endure regular compressions and extensions.

 

Floor to floor joint before testing. Notice temperature measurement points.6

BEYOND FIRE RESISTANCE: SECONDARY ATTRIBUTES OF FIRESTOP

L-rating

We started this article by mentioning that firestop systems can be used to restrict the movement of air. Indeed, this attribute is determined by an L-rating (L for leakage), which determines the suitability to restrict the passage of air and smoke. The test is performed according to UL 1479, and it measures the amount of air leakage through the firestop system. The test is performed at different temperatures and is measured in CFM (cubic feet per minute). The lower the number, the better the L-rating. This rating is particularly handy also when used in presence of fire suppression systems, which most of the times must guarantee a certain concentration of the suppression agent in the protected room for a determined amount of time for it to work.

W-rating

This attribute describes the effectiveness of a firestop system to restrict the flow of water. Try to think about how important containing rainwater can be specially during construction in floor penetrations. After the building is occupied, fire stop systems in penetrations or edge of slab with a W-rating come in handy when there are major plumbing leaks or accidents.

FIRESTOP SYSTEM FACTORS

Now that we have a grasp on the basics of compartmentation, fire tests and why it’s important to restore the integrity of fire rated assemblies, we can identify all the factors that we need to consider to choose the correct firestop system. The first thing is to identify if we are dealing with a penetration or a joint. After that, the factors we must consider are listed below.

Through Penetrations

  1. Size and type of penetrating item(s): Depending on your trade, you might be installing 4-inch steel pipe with a sleeve, ¾ inch conduit, or a bundle of cables.
  2. Size and shape of opening: 8 inch in diameter, a 4-inch x 4-inch square, or maybe just an irregular hole in the wall.
  3. Annular space: This is the space between the item and the opening. If it’s a single item, you usually have two measurements, a minimum and a maximum. Try to picture an opening that is much larger than the penetrating item, and you will figure out that just a sealant is not enough to fill the space (let alone pass the hose stream test!). A filling material such as mineral wool or a device might be necessary.
  4. Fire rating of the assembly: 1-hour, 2-hour, 3-hour or 4-hours.
  5. Wall or Floor type: pre-cast hollow core floor, or maybe a gypsum shaft wall.
  6. Wall or Floor thickness: 4-1/2 inch, or maybe gypsum with 3-5/8 inch studs.
  7. Secondary attributes: maybe you need an L rating of less than 1 CFM.

Joints

  1. Movement requirement:5% required for compression or extension, or maybe not required at all (an architect or engineer should be helping you!)
  2. Joint width: Maybe 1-inch top of wall, or a metal deck with 3-inch flutes.
  3. Fire rating: 1-hour, 2-hour gypsum walls, or 3-hour, 4-hours concrete floors.
  4. Wall or floor type: wood, masonry, concrete or gypsum.
  5. Wall of floor thickness: minimum 2-1/2 inch, for example.

CHOOSE THE CORRECT SYSTEM

That’s it. All we needed is to understand that firestop protection is a system that considers all the factors we just learned about, and we are ready to choose the correct system for our application. Fortunately, most suppliers have, at our disposition, Firestop Submittal Builders readily available for us online. Once we give them the input of our factors, they will give us various UL listed approved options.

Let’s look at a typical case. Imagine you are in a construction project, you are installing steel pipe, and you know that the maximum size you are using is 2 inches. You run into a 4 ½ inch block wall, you open a hole and you go through. When you measure, you realize you are touching the opening from the top of the pipe, and you have 2 inches of clearance below the pipe. You look at your architectural drawings and you realize the fire rating of the wall is 2-hours. There’s no mention on the notes or specs about secondary attributes. Do you have everything you need? Let’s look at our factors:

Through Penetrations

  1. Size and type of penetrating item(s): Maximum 2-inch steel pipe, no sleeve.
  2. Size and shape of opening: Maximum 4-inch opening.
  3. Annular space: Minimum: 0 inches (point of contact), Maximum: 2 inches.
  4. Fire rating of the assembly: 2-hour fire rated.
  5. Wall or Floor type: Concrete block wall
  6. Wall or Floor thickness: 4-1/2 inches
  7. Secondary attributes: None

So, we have all our factors! Let’s use the firestop submittal generator from HILTI for this example. If we enter our factors one by one, the first option that we get is the UL System No. C-AJ-1421, for metal pipes going through block walls. All we need to do is double check that the drawing satisfies our factors and then we need to follow the steps on the drawing. This solution works with mineral insulation and firestop sealant from HILTI and must be installed as directed by the drawing.

 

ENGINEERING JUDGEMENTS

The UL library for different firestop systems from many manufacturers is very large and is ever growing. Nevertheless, it is impossible to have a test that contemplates every single scenario. Maybe the shape of the opening is too irregular, or we have multiple and different penetrating items, and we can’t find a UL listed solution from any manufacturer.  This is where Engineering Judgements (EJs) come into play.

An engineering judgment is a drawing usually produced by a firestop manufacturer for a jobsite-specific application. They are a valid solution when a customer’s jobsite condition is different from any tested firestop system. Most firestop manufacturers are open to receive requests directly from customers. If they deem the application and the solution as possible, they will produce a drawing that will have the address of the jobsite and will only carry value to that specific job.

MANUFACTURER FIRESTOP SUBMITTAL BUILDERS

Below is information for browsing through some of the UL listed firestop approved systems from HILTI, STI, 3M and METACAULK.

 

    Alejandro Uribe, PE, CFPS, CET

    1. “The life safety triangle”

    Firestopping plan review and inspection of joints

    https://www.iccsafe.org/wp-content/uploads/Firestopping-Plan-Review-and-Inspection-of-Joints.pdf

     

    1. “MGM Grand Hotel and Casino fire, 1980, Las Vegas, Nevada”

     

    1. “AHJ HANDBOOK”

    Intertek

    www.intertek.com/building/certification

     

    1. “Playing with Fire”

    RIBA journal

    https://www.ribaj.com/products/playing-with-fire

     

    1. “Time-Temperature Curve”

    Confinement of Fire in Buildings

    NFPA Fire Protection Handbook, 18-4, Volume II, 20th Edition

     

    1. “Full-Scale Wall Assembly”

    Firestop Testing – FCIA, in coordination with UL

    https://studylib.net/doc/18508979/firestop-testing-%E2%80%93-fcia

     

    1. “Through penetrations vs Membrane penetrations”

    ARCHTOOLBOX

    https://www.archtoolbox.com/images/materials/thermal/through-membrane-penetrations.png

     

    Inspection & Testing of Water-Based Systems
    Basic Reference Text

    $109.99

    The fifteen chapter Inspection & Testing of Water-Based Systems Basic Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.


    The Inspection & Testing of Water-Based Systems Basic Reference Text covers:

     

    I&T Sprinkler basic reference text

    Inspection & Testing of Water-Based Systems
    Intermediate Reference Text

    $109.99

    The fifteen chapter Inspection & Testing of Water-Based Systems Intermediate Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exams.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Inspection & Testing of Water-Based Systems Intermediate Reference Text covers:

     

    I&T intermediate reference text, Sprinklers

    Inspection & Testing of Fire Alarm Systems
    Reference Text

    $139.99

    This fourteen chapter Inspection & Testing of Fire Alarm Systems Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Inspection & Testing of Fire Alarm Systems Level I & II Online Course is a perfect study package for those preparing for the NICET Inspection & Testing of Fire Alarm Systems exams.
    This book is a fundamental reference covering Inspection & Testing of Fire Alarm Systems concepts. The numerous NFPA 72 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


    The Inspection & Testing of Fire Alarm Systems Reference Text covers:

     

    I&T fire alarm systems reference text

     

    Water-Based Systems Layout Basic Reference Text

    $119.99

    The twenty chapter Water-Based Systems Layout Basic Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 237 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Water-Based Systems Layout Basic Reference Text covers:

     

    Sprinkler reference text

    Water-Based Systems Layout Intermediate Reference Text

    $139.99

    The twenty three chapter Water-Based Systems Layout Intermediate Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 339 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level II exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Water-Based Systems Layout Intermediate Reference Text covers:

     

    Water based systems, sprinkler intermediate reference text

    Water-Based Systems Layout Advanced General Plans Reference Text

    $139.99

    The sixteen chapter Water-Based Systems Layout Advanced General Plans Reference text is an invaluable reference for Water-Based Systems Layout professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, General Plans exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Water-Based Systems Layout Advanced General Plans Reference Text covers:

     

    Sprinkler systems general plans reference text

    Water-Based Systems Layout Advanced Hydraulics Reference Text

    $139.99

    The eight chapter Water-Based Systems Layout Advanced Hydraulics Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 232 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, Hydraulics exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Water-Based Systems Layout Advanced Hydraulics Reference Text covers:

     

    Advanced hydraulics sample reference text page

    Water-Based Systems Layout Basic & Intermediate Reference Texts

    $229.99

    Two GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



    Water-Based Systems Layout Basic Reference Text

    $119.99

    The twenty chapter Water-Based Systems Layout Basic Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 237 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

     



    Water-Based Systems Layout Intermediate Reference Text

    $139.99

    The twenty three chapter Water-Based Systems Layout Intermediate Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 339 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level II exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    Detailed contents can be found in the description for the individual text.

     

    Water-Based Systems Layout Basic, Intermediate, General Plans & Hydraulics Reference Texts

    $449.99

    Four GREAT Reference Texts, One Low Price! Save when you order the Complete Water-Based Reference Library. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.


    Detailed descriptions can be found in the “Learn More” link for each individual text.

    Water-Based Systems Layout General Plans & Hydraulics
    Reference Texts

    $249.99

    Two GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



    Water-Based Systems Layout General Plans Reference Text

    $149.99

    The sixteen chapter Water-Based Systems Layout Advanced General Plans Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 335 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, General Plans exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.



    Water-Based Systems Layout Hydraulics Reference Text

    $149.99

    The eight chapter Water-Based Systems Layout Advanced Hydraulics Reference text is an invaluable reference for Water-Based Systems Layout professionals. This text contains 232 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Water-Based Systems Layout Level III, Hydraulics exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    Detailed contents can be found in the description for the individual text.

     

    Inspection & Testing of Water-Based Systems Basic & Intermediate Reference Texts

    $189.99

    Two GREAT Reference Texts, One Low Price! $ave when you order the combo package. Loaded with NFPA 25 references, these texts will become a valuable asset both in the field and office.



    Inspection & Testing of Water-Based Systems Basic Reference Text

    $109.99

    The fifteen chapter Inspection & Testing of Water-Based Systems Basic Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

     



    Inspection & Testing of Water-Based Systems Intermediate Reference Text

    $109.99

    The fifteen chapter Inspection & Testing of Water-Based Systems Intermediate Reference text is an invaluable reference for Water-Based Systems professionals. The detailed explanations and outlines are perfect for those preparing for the NICET Inspection & Testing of Water-Based Systems exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    Detailed contents can be found in the description for the individual text.

     

    Special Hazards Basic Reference Text

    $139.99

    The 18 chapter Special Hazards Basic Reference text is an invaluable reference for Special Hazards’ professionals. This text contains 265 pages. The detailed explanations and outlines are perfect for those preparing for the NICET Special Hazards Level I exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    The Special Hazards Basic Reference Text covers:

    Fire Alarm Systems – Basic Reference Text

    $119.99

    This thirteen chapter Fire Alarm Systems – Basic Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level I Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level I exam.
    This book is a fundamental reference covering Fire Alarm Systems concepts. The numerous NFPA 70 2014 and NFPA 72 2016 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


    The Fire Alarm Systems Reference Text covers:

    Fire Alarm Systems – Basic, Intermediate & Advanced Texts, Inspection & Testing of Fire Alarms Text, Inspection & Testing of Water-Based Systems Basic & Intermediate Texts, Special Hazards Text, and Water-Based Systems Layout Basic, Intermediate, General Plans & Hydraulics Reference Texts

    $999.99

    Eleven GREAT Reference Texts, One Low Price! Save when you order the Complete Fire Tech Reference Library. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.


    Detailed descriptions can be found in the “Learn More” link for each individual text.

    Prior to joining Fire Tech Productions, Tom Frericks Jr. owned Copp Integrated Systems in Dayton, OH.  He served on the NSCA board of directors for 11 years and is currently serving on the ASCET and NICET boards.  Tom received NSCA’s 2018 Per Haugen Lifetime Achievement Award for his time and dedication to the association.

    All Inclusive Pricing includes workshop registration, hotel stay, meals & shuttle to/from training site.

    Live in the area? Call our office at 937-434-3473 for Non-Inclusive Pricing.

    Packages Include:

    The following NICET approved Standards and Fire Tabs in addition to your Online Course purchase:

    Level I: NFPA 70 2011 and NFPA 72 2013

    Level I & II: NFPA 70 2011, NFPA 72 2013 and IBC 2012

    Level III: NFPA 70 2011, NFPA 72 2013, IBC 2012 and NFPA 101 2012

    What Is a Webinar?

  • Four hours of supplemental content expanding on course lesson material.
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 70, NFPA 72, IBC, and NFPA 101 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 70 2014, NFPA 72 2016 and Ugly’s
  • Level II: NFPA 70 2014, NFPA 72 2016 and IBC 2015
  • Level III: NFPA 70 2014, NFPA 72 2016, NFPA 101 2015 and IBC 2015
  • We know preparing for a NICET exam doesn’t happen overnight. Fire Tech’s programs are designed to guide you every step of the way. If you have followed our NICET prep program, and have taken the exam within thirty (30) days of successfully completing your course* and do not pass, Fire Tech Productions will provide the following support:

    – Evaluation of your exam results to uncover subject matter weaknesses;
    – Recommendations for improved exam preparation & testing; and
    – Extended access to appropriate prep course(s)

    Students must contact Fire Tech Productions and restart their study within ninety (90) days of failing the exam.

    *Our courses are guaranteed for exam success when students who possess the level of experience (corresponding with the certification requirements) have studied each lesson & taken and passed each quiz/exam within each level of training, up to and including their exam level. Students must have also used current NICET-permitted references for their study and exam.

    Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • 10-15 minute videos accompany each individual lesson.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 13, 13D, 13R, 14, 20 and 291 2016 and NFPA 22 2013 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 13, 13D, 13R and 291 2016
  • Level II: NFPA 13, 14, 20 and 291 2016
  • Level III – General Plans: NFPA 13, 14, 20 2016 and 22 2013
  • Level III – Hydraulics: NFPA 13, 14, 20 and 291 2016
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 12 and 70 2011, NFPA 72 2013 and NFPA 2001 2012 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved Standards in addition to your Online Course:

  • Level I: NFPA 12 and 70 2011, NFPA 72 2013 and NFPA 2001 2012
  • Online Courses Include:

  • 90 days (single level purchase) / 120 days (multiple level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 72 2013 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I & II: NFPA 72 2013
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I & II: NFPA 25 2014
  • Online Courses Include:

  • 90 days (single level purchase) / 120 days (multiple level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 25 2014 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Exam Allowable References Include:

    The following NICET approved tabbed Standards:

  • Level I & II: NFPA 25 2014
  • To purchase individual standards, click here.

    Exam Allowable References Include:

    The following NICET approved tabbed Standards:

  • Level I & II: NFPA 72 2013
  • To purchase individual standards, click here.

    Exam Allowable References Include:

    The following NICET approved tabbed Standards:

  • Level I: NFPA 12 and 70 2011, NFPA 72 2013 and NFPA 2001 2012
  • To purchase individual standards, click here.

    Exam Allowable References Include:

    The following NICET approved tabbed Standards:

  • Level I: NFPA 13, 13D, 13R and 291 2016
  • Level II: NFPA 13, 14, 20 and 291 2016
  • Level III – General Plans: NFPA 13, 14, 20 2016 and 22 2013
  • Level III – Hydraulics: NFPA 13, 14, 20 and 291 2016
  • To purchase individual standards, click here.

    Exam Allowable References Include:

    The following NICET approved tabbed Standards:

  • Level I: NFPA 70 2014 and NFPA 72 2016
  • Level II: NFPA 70 2014, NFPA 72 2016 and IBC 2015
  • Level III: NFPA 70 2014, NFPA 72 2016, NFPA 101 2015 and IBC 2015
  • To purchase individual standards, click here.

    Fire Alarm Systems – Intermediate Reference Text

    $119.99

    This fourteen chapter Fire Alarm Systems – Intermediate Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level II Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level II exam.
    This book is a fundamental reference covering Fire Alarm Systems concepts. The numerous NFPA 70 2014, NFPA 72 2016 and IBC 2015 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


    The Fire Alarm Systems – Intermediate Reference Text covers:

    Fire Alarm Systems Basic & Intermediate Reference Texts

    $209.99

    Two GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



    Fire Alarm Systems Basic Reference Text

    $119.99

    This thirteen chapter Fire Alarm Systems – Basic Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level I Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level I exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.


    Detailed contents can be found in the description for the individual text.

     



    Fire Alarm Systems Intermediate Reference Text

    $119.99

    This fourteen chapter Fire Alarm Systems – Intermediate Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level II Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level II exam.

    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

     



    Fire Alarm Systems – Advanced Reference Text

    $119.99

    This nine chapter Fire Alarm Systems – Advanced Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level III Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level III exam.
    This book is a fundamental reference covering Fire Alarm Systems concepts. The numerous NFPA 70 2014, NFPA 72 2016, NFPA 101 2015 and IBC 2015 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


    The Fire Alarm Systems – Advanced Reference Text covers:

    Fire Alarm Systems Basic, Intermediate & Advanced Reference Texts

    $309.99

    Three GREAT Reference Texts, One Low Price! Save when you order the combo package. Loaded with NFPA references, these texts will become a valuable asset both in the field and office.



    Fire Alarm Systems Basic Reference Text

    $119.99

    This thirteen chapter Fire Alarm Systems – Basic Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level I Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level I exam.



    Fire Alarm Systems Intermediate Reference Text

    $119.99

    This fourteen chapter Fire Alarm Systems – Intermediate Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level II Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level II exam.



    Fire Alarm Systems Advanced Reference Text

    $119.99

    This nine chapter Fire Alarm Systems – Advanced Reference text is an invaluable reference for Fire Alarm Systems Technicians and Professionals. Coupling this text with our Fire Alarm Systems Level III Online Course is a perfect study package for those preparing for the NICET Fire Alarm Systems Level III exam.
    This book is a fundamental reference covering Fire Alarm Systems concepts. The numerous NFPA 70 2014, NFPA 72 2016, NFPA 101 2015 and IBC 2015 references, charts and graphs make the text easy to read and follow. This well-written text will become the cornerstone of your Fire Protection Library!


    *Fire Tech Productions recommends their online NICET prep courses for the best preparation possible.

    Detailed contents can be found in the description for the individual text.

    Webinars Include:

  • Over 2 hours of recorded content covering 12 key subjects.
  • Monthly Instructor Led Q&A sessions available for registration after purchase.
  • Webinars were designed to supplement the Water-Based Layout Level I Online Course.
  • Video Series Include:

  • Video content covering 12 key subjects.
  • Videos were designed to supplement the Water-Based Layout Level I Online Course.
  • Online Courses Include:

  • 90 days (single level purchase) / 120 days (multiple level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 72 2016, NFPA 92 2018 and OSHA 29 CFR 1926 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 72 2016 and OSHA 29 CFR 1926
  • Level II: NFPA 72 2016 and NFPA 92 2018
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 13 2016, NFPA 16 2015, NFPA 20 2016, NFPA 25 2017, NFPA 72 2016, NFPA 291 2016.
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 25 2017
  • Level II: NFPA 20 2016, NFPA 25 2017, NFPA 72 2016, NFPA 291 2016
  • Level III: NFPA 13 2016, NFPA 16 2015, NFPA 25 2017, NFPA 72 2016
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.
  • Packages Include:

    The following NICET approved tabbed Standards in addition to your Online Course:

  • Level I: NFPA 72 2016
  • Level II: NFPA 72 2016 and NFPA 92 2018
  • Online Courses Include:

  • 90 days (single level purchase) self-paced study online access.
  • Simulated online exams for maximum practice and preparation; 100s of sample questions.
  • Course content continually reviewed and updated.
  • Detailed review of NFPA 13, 13D, 13R, 14, 20 and 291 2016 and NFPA 22 2013 (per level of study).
  • Effective tips, hints and test strategies to help lead you to exam day success.
  • Certificate upon successful completion of the course.
  • A thorough understanding of NICET and the certification process.